Powered by Blogger.
RSS

[tabtrailers] Surge Protector EMS-HW30C

 

The electrical management system
EMS-HW30C
That many of you have pruchased have asked me how to set it up for 136 second delay to protect the "COOL CAT" compressor. Cool Cat requires 2 minutes or 120 seconds.
If you open the box, next to the plug for the remote (telephone wire type jack) there is a J6 jumper pin. A little black piece that goes across 2 pins. Simply remove that Black jumper and it is now set for 136 second delay.

If anyone else is looking to purchase one of these this is the info you will need that is not exactly spelled out in the install instructions.

Once again I believe IMO that this is a great unit and works very well against all the issues that can come at you in a campground park.
It protects more than just a surge.
Low Voltage can be even worst on a compressor and when it's hot and all those air conditioners fire up, watch the voltage drop in a camp ground.
Below a 105 volts can be very bad for things like your compressor, converters, fans, computers, the list goes on. So be prepared and protect yourself with some type of Surge (Electrical managemnt system)